90 kVA (72kW) Multi-Output Diesel Cart 6022
Description
Aviation Ground Equipment Corp., a leader in military ground support equipment industry saw the need in the fleet for a modern and easy to use alternative to the aging fleet of Essex B809’s and John Hollingsworth -86’s which gave birth to the AGEC 6022 series of ground power units. The AGEC 6022 series allows the user to choose the features that best suit their application using a 90kVA 400Hz unit as the base. The AGEC 6000 series of ground power units is the ideal solution for all military applications from land-based theaters to shipboard environments.
REQUEST A QUOTE
Features
- AC Output: 115/200 VAC, 400 Hz, 90 kVA @0.8 PF (72 kW), Meets MIL‐STD‐704F
- Smart Control User Interface
- Built‐In Test Diagnostics (BIT) with Fault Recording
- Rugged Four‐Wheeled Trailer, Hand Brake System, SAE AS 8090, Type II, Group C
Output Specifications
- 400 Hz. Output – 115/200 VAC
- Ratings: 72 kW (90 kVA @ 0.8 PF)
- Overloads:
- 125% – 5 minutes
- Meets or Exceeds MIL-STD-704F
- 28 VDC Output (optional)
- Ratings: 600 amps continuous
2000 amps starting current - Overloads:
- 125% – 5 minutes
- 150% – 5 seconds
- Meets or Exceeds MIL-STD-704F
- Ratings: 600 amps continuous
- 270 VDC Main Output
- Ratings: 72 kW (continuous)
- Overloads:
- 125% – 5 minutes
- 200% – 5 seconds
- Meets or Exceeds F-35 (JSF) Specifications
Military and Commercial Standards
- MIL-STD-704F
- MIL-STD-461E
- MIL-STD-167-1
- MIL-STD-810F
- MIL-STD-209
- MIL-STD-889
- MIL-STD-1472
Weight & Dimensions
- Dimensions 66”H X 66”W X 108”L (Tow bar Stowed)
- Weight 5,450 lbs.
Engine Specifications
- Cummins QSB 4.5 Turbocharged 4-stroke, inline 4 cylinder common rail fuel system
- Full Cummins application approval
- 12 VDC battery system
- ECM Electronic governor system
- Lubricity Filter allows engine to operate on aviation fuels
- Intake manifold pre-heater (grid heater)
Compares To NSN's
- Hobart NSN’s: 6115-01-297-3761 (AM32A-86E) , 6115-01-558-3112 (60CU24 , ACE60CUTT3) , 6115-01-600-4301 (60CU20) , 6115-01-541-6297 ( 90CU20P5) , 6115-01-651-9087 (4400 90kVA / 60kVA)
- Hollingsworth NSN’s: 6115-01-155-2340 (-86)
- Essex NSN’s: 6115-01-389-4093 (B809A), 6RX6115-01-437-1209 (B951) , 6115-01-502-7927 (B809D)
Compares To
- Jetall: JTL60D (60kVA), JTL90D (90kVA)
- Trilectron: 60T400(60kVA) , 90C400SLN & 90D400SLN (90kVA)
- Houchin: C690-90 (90kVA)
- Tug Technologies/Davco: GPU400/60 (60kVA), GP400-100 (90kVA)
- FCX Systems:GPU060-C & GPU060-1(60kVA), GPU090-C-1 (90kVA)
- TLD: GPU-409-E-CUP(90kVA) , GPU-406-E-CUP (60kVA)
- Essex Electro Engineers: A700A (60kVA) , A934C (60kVA) , B809 (90kVA) , B809A (90kVA) , B809C (90kVA) , A/M32-108 (90kVA) , B809D (90kVA) , BD809D-1 (90kVA)